Ringing wave is caused by the switching of power supply and control line or lightning strike, and appears on the terminal of the equipment🀅. Ringing wave may affect the reliable operation of equipment and system. The ringing wave generator is used to evaluate the performance of electrical and electronic equipment, devices or systems subjec😼ted to ringing waves. The product meets the requirements of new standards such as iec61000-4-12 and gb/t17626.12.
Product model
output voltage
oscillation frequency
Pulse polarity
internal resistance
Pulse front
Pulse repetition rate
Burst interval
Number of pulses
phase
Coupling / decoupling network
Working power supply
ambient temperature
RWIT6
0.25~6KV
100kHz
Positive, negative, positive before negative, negative before positive
12Q、30 Q、200 Q
Current rise time S1 us; Voltage rise time ± 0.5us ± 20%
Up to 60 times / minute
1s ~ 9999s
1~9999 times
0~359 ° or asynchronous
Three phase five wire, 16A
AC 220V ± 10% 50/60Hz
15C~35 ℃