2020 官网升级中!现在您访问官网的浏览器设备分辨率宽度低于1280px请使用高分辨率宽度访问。
EMC tester is a multifunctional combined immunity test equipment that can carry out three tests of electrostatic discharge immunity, electrical fast transient pulse group immunity and surge (impact) immunity. The three test functions can be combined freely. The products meet the requirements of IEC61000-4-2, iec61000-4-4, iec61000-4-5, gb/t17626.2, gb/t17626.4, gb/t17626.5 and other new standards. EMC s03-w includes three tests: electrostatic discharge immunity, electrical fast transient pulse group immunity and surge (impact) immunity. EMC s02-w includes two tests of electrical fast transient burst immunity and surge (impact) immunity. EMC s02-e includes two tests of electrostatic discharge immunity and surge (impact) immunity. EMC s02-f includes two tests: electrostatic discharge immunity and electrical fast transient burst immunity. 🧔 The product adopts a built-in fully automatic coupling / decoupling network and a full touch screen operation interface, and its performance is comparable to that of imported brands.
Electrostatic discharge immunity
output voltage
Output voltage polarity
Energy storage capacitance
Discharge resistance
Rise time of discharge current
Air discharge holding time
Discharge mode
Discharge mode
Trigger mode
Working mode
Discharge interval
Discharge times
Electrical fast transient burst immunity
Burst output voltage
Burst frequency
Group polarity in pulse
Burst run time
Impulse group internal resistance
Pulse front
pulse width
Number of pulses
Pulse train period
Phase angle
Coupling / decoupling network
Surge (impact) immunity
Surge waveform
Open circuit voltage
short-circuit current
Surge polarity
Phase angle
Output impedance
Coupling / decoupling network
Surge coupling mode
frequency
I interval time
-
0.2~±20kV
Positive, negative, positive before negative, negative before positive
150pF
330Q
0.6~1ns
≥5s
Contact discharge, air discharge
Single discharge, continuous discharge
Automatic, manual and gun body control
IEC level mode, programming mode, voltage ramp up mode
0.05~9.99s
1~9999 times
-
0.2 ~ ± 5kV
1khz~1200khz, continuously adjustable
Positive or negative, positive before negative, negative before positive
1~9999s, continuously adjustable
50 Q
5ns
50ns (50Q load) /35 ns~150 ns (1kq load)
1~255, continuously adjustable
0.15~99.9s, continuously adjustable
0~360 ° synchronous or asynchronous
Built in, single-phase three wire, 16A
-
Voltage wave: 1.2/50 us; Current wave: 8 /20 us
0.2~6kV
0.1~3kA
Positive or negative, positive before negative, negative before positive
0~359 ° synchronous or asynchronous
2q (common mode 12q)
Built in, single-phase three wire, 16A
Differential mode 18uf, common mode 9uf /10q
1~9999 times
10~9999s